ECOJOHN WC5-Mini-P12 Toilet Waste Combustion System 10 GPD 12V DC Propane/Natural Gas.

Price: Call For Price
+ -
Usually ships within 2 weeks
SKU: EHNWC5MINIP12


Shipping Weight:
150.0 LBS
Shipping Dimensions
Length: 24 In
Width: 16 In
Height: 25 In
WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.gov

ECOJOHN WC Series Description

WC series and use Propane, Diesel, or Natural Gas as fuel source depending on model and size. The waste combustion systems are ideal for a variety of situations. For example, in remote areas, agricultural areas, and large acreage properties, where there is no access to a City or County sewage system, this is a great alternative. In addition to new installations, a system can be installed and connected to existing toilets. Thus in case there is an issue with failing or too costly sewage solutions one can add on a waste combustion system and eliminate the problems.

The incinerators along with low flush toilets provide ecological, economical, and logistical benefits. The WC models have the capability to incinerate between 1 to 5 gallons of waste per hour (depending on model).

ECOJOHN WC5-Mini Typical Application

  • Small Homes
  • Cabins
  • Summer Homes
  • 2-3 Persons
  • Low Capacity Usage Areas

ECOJOHN WC5-Mini Superior Features

  • Incinerates black water from a waste holding tank
  • No Chemicals
  • 12VDC, 120V AC, or 240V AC Options Available (model specific)
  • Diesel, Propane, and Natural Gas (model specific)
  • Meets emission regulations
  • Can be used in cold climates and or high elevation
  • CSA and CE approved

ECOJOHN WC5-Mini Operation

  • A low-flush toilet dissolves the waste with the built in macerator pump
  • Standard dual flush toilets or vacuum toilets may be used
  • Multiple toilets can be connected to one system
  • Showers, sinks, and urinals may also be connected to the system
  • Toilets can be used during the incineration
  • Moves black water into waste tank
  • Sensor signals level in tank
  • Automatically pump in waste water and commence incinerator when waste tank fills up
  • Pump and burn process repeats itself until waste tank is empty
  • Puts itself in standby when the waste tank is empty
  • May be set in Manual, Automatic Mode, or Timer Mode
  • May be set to commence incinerator at a certain time i.e. midnight
  • Easy operating control panel
  • Control panel displays multiple functions i.e. temperature, levels in tanks

ECOJOHN WC5-Mini-P12 12V DC Specifications

  • POWER SOURCE: 12V DC
  • ELECTRICAL CONSUMPTION: 11-12 Amp @ 12V DC
  • FUEL TYPE: propane
  • FUEL CONSUMPTION RATE: 0.47 lbs/hr
  • BURNING CAPACITY: 0.5 gal/hour
  • OPERATING TEMPERATURE: 32F to 140F
  • DIMENSIONS: 25" H x 16" W x 24" D
  • WEIGHT: 130 lbs

SAFETY AND EMISSION

The incinerator is a very safe and convenient appliance when assembled and used properly. In order to provide a high quality system, we have chosen to only use top quality materials that are made to withstand high usage and severe environment. During the production, it goes through several meticulous testing procedures to monitor quality control. The products have also been approved and certified by several worldwide testing agencies such as CE and CSA. The incinerators are equipped with very efficient burners that ensure safety, reliabilty and very low emission.


WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.govWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

ECOJOHN WC5-Mini Installation

The components in the system are plug-and-play which makes the installation process uncomplicated. Below are some basic facts about the installation:

  • The incinerator must be placed above ground
  • Waste holding tank and incinerator can be placed up to 300 ft away from toilet
  • Incinerator and waste tank must be installed within 10 ft of each other unless the incinerator is installed below the waste tank i.e. crawl space.
  • The incinerator can be installed up to 5 ft above the waste tank
  • Incinerator must be installed inside a weather proof building/structure
  • Incinerator requires 5 inches clearance from any wall
  • 1 ft clearance is recommended in front of the clean out door and burner door on the incinerator
  • Should not be installed or operated in an area where there is a risk of an accumulation of flammable vapors or dust
  • The chimney has to be a minimum of 7 ft long
  • The chimney can be vented out through the side wall using elbows

ECOJOHN WC5-Mini Maintenance & Cleaning

The waste combustion system is a very reliable in operation and maintenance free if operated as per the manufacturer's instructions. The maintenance can easily be done by one person and consists of filling up water in water tank (unless a pressurized water system is used), filling up fuel, and periodically empty ashes from burn chamber.