Prev Next
In Stock!

Myers ME750120T Cast Iron Effluent Pump 0.5 HP 115V 20' Cord Automatic

Usually ships within 24 hours.
In Stock Quantity: 1
SKU: MYRME750120T


Shipping Weight:
62.0 LBS
Shipping Dimensions
Length: 15 In
Width: 11 In
Height: 15 In
WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.gov

myerslogopumps1.png

Myers ME7 Series Cast Iron Effluent Pump Descriptions

The Myers ME7 Cast Iron Effluent Pumps are designed for sewage, effluent and watstewater removal, sump drainage, liquid transfer systems, circulation, dewatering and flood control. Pump motors range from a 115V or a 230V single phase to a 208-230V or 460V three phase. All models come with a 20' 3-prong grounding type cord and plug. They are rated for continuous duty when fully submerged in a liquid with a maximum temperature of 105° F (40.5° C)

Myers ME7 Series Cast Iron Effluent Pump Typical Applications

  • Effluent and Wastewater Removal
  • Sump Drainage
  • Dewatering
  • Flood Control

Myers ME7 Series Cast Iron Effluent Pump Features

  • Bearing and Mechanical Seal – Permanently Lubricated for Long Life.
  • Overload Protection – Built-In Thermal Overload with Automatic Reset.
  • Cord Design – Prevents Oil Loss From and Moisture Protection for Motor.
  • Serviceability – Heavyduty Lift-Out Ring, Field Serviceable.
  • Solids Handling – 3/4” Spherical Capability.
  • Stainless Steel Hardware – Allows for Easy Disassembly After Extended Service.
  • Controls – Standard Controls Available for Automatic Operation.
  • Float – Mechanical (Non Mercury).

Myers ME750120T Cast Iron Effluent Pump Specifications

  • VOLTAGE: 1ø, 115V, 60 Hz
  • HORSEPOWER: 0.5 HP
  • AMP DRAW (full load): 13.0
  • MOTOR TYPE: Permanent Split Capacitor (PSC)
  • RPM: 3450
  • MAXIMUM HEAD: 60'
  • MAXIMUM CAPACITY: 110 GPM
  • SWITCH TYPE: Tethered
  • SWITCH 'ON' LEVEL: 18” (459.7 mm)
  • SWITCH 'OFF' LEVEL: 9” (231.1 mm)
  • DISCHARGE PIPE SIZE: 2.0" NPT
  • MAXIMUM SOLIDS HANDLING: 3/4"
  • IMPELLER TYPE: Thermoplastic Vortex
  • CORD LENGTH: 20' Oil and Water Resistant
  • CORD SIZE: 16-3 Type; SJTW-A/SJTW w/Integrally Grounded 3-Prong Plug
  • BODY CONSTRUCTION: Cast Iron
  • MAXIMUM LIQUID TEMPERATURE: 130°F (55C)
  • DUTY RATING: Continuous at Max Temperature of 105° F (40.5° C)

Myers ME7 Series Cast Iron Effluent Pump Performance Data

me7curve.jpg


WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.govWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

MYERS LIMITED WARRANTY

Myers® warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period shown below

ProductWarranty Period whichever occurs first:
Jet pumps, small centrifugal pumps, submersible pumps and related
accessories
12 months from date of original installation, or 18 months from date of manufacture
Fibrewound Tanks5 years from date of original installation
Fibrewound Tanks5 years from date of original installation
Sump/Sewage/Effluent Products12 months from date of original installation, or 36 months from date of manufacture
Battery Backup Units
MBSP-2, MBSP-2C
MBSP-3, MBSP-3C
12 months from date of original installation, or 18 months from date of manufacture
24 months from date of original installation, or 30 months from date of manufacture
Wastewater Solids Handling Pumps12 months from date of shipment from factory or 18 months from date of manufacture

Our warranty applies only where such products are used in compliance with the requirements of the applicable product catalog and/or manuals. For additional information, please refer to the applicable standard limited warranty featured in the product manual.

Our warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, improper installation, or improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase power through a phase converter will void the warranty. Note also that three phase motors must be protected by three-leg, ambient compensated, extra-quick trip overload relays of the recommended size or the warranty is void.

Your only remedy, and MYERS’s only duty, is that MYERS repair or replace defective products (at MYERS’s choice). You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered. No request for service will be accepted if received after the Warranty Period has expired. This warranty is not transferable.

MYERS SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.

THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN.

Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an implied warranty, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from state to state.

This Limited Warranty is effective April 1, 2014 and replaces all undated warranties and warranties dated before April 1, 2014.

We've been helping customers since 1953

Trust Guard Security Scanned