Myers P50 Series Cast Iron Effluent S.T.E.P. Pump Description

The Myers P Series Effluent Pumps are designed specifically for multi-pump pressure collection, septic tank effluent pumping (S.T.E.P) and high head drainage applications. The high efficiency, single-vane, enclosed impellers provide steep, non-overloading performance curves, which are ideal for these applications. These pumps deliver more capacity at higher heads than most pumps in this class. The combination of the most rugged materials ensure years of trouble-free, dependable service.

Myers P50 Series Cast Iron Effluent S.T.E.P. Pump Typical Applications

  • Effluent Removal
  • Trench and Mount Pressure Dose Systems
  • Sump Drainage
  • Water Transfer
  • Flood Control

Myers P50 Series Cast Iron Effluent S.T.E.P. Pump Features

  • P Series Effluent Pumps are Designed for Years of Maintenance-Free Operation
  • Single-Vane, Enclosed Impeller Provides Steep, Non-Overloading Performance Curve for Pressure Collection and ST.E.P. Systems; Outperforms Most Pumps in its Class
  • Enclosed Impeller Eliminates the Possibility of Jamming or Corrosion Between Impeller and Volute
  • Passes 3/4" Spherical Solids
  • Durable Motor Will Deliver Many Years of Reliable Service
  • Oil-Filled Motor for Maximum Heat Dissipation and Continuous Bearing Lubrication
  • High-Torque, Permanent Split Capacitor (PSC), Single-Phase Motors; No Starting Switches or Relays to Wear Out
  • Double Tandem Seal Configuration for Extra Motor Protection, Tough Effluent Pumping Applications
  • Optional Seal Leak Probes Warn of Seal Leak Condition; Helps Prevent Costly Motor Damage
  • On-Winding Current and Temperature-Sensitive Overload to Protect Against Costly Burnout
  • Volute Seal Ring is Replaceable; Restores Pump to Original Performance if Wear Should Occur
  • Motor is Held in Place by 4 Screws; Easily Removed if Service is Ever Needed
  • Does Not Include Seal Leak Detector Probes

Myers P51 Cast Iron Effluent S.T.E.P. Pump Specifications

  • VOLTAGE: 1ø, 115V, 60 Hz
  • HORSEPOWER: 0.5 HP
  • MOTOR TYPE: Permanent Split Capacitor (PSC)
  • RPM: 3450
  • MAXIMUM HEAD: 80'
  • MAXIMUM CAPACITY: 57 GPM
  • SWITCH TYPE: Manual
  • MINIMUM SUMP DIAMETER: Simplex: 24” Duplex: 36”
  • DISCHARGE PIPE SIZE: 1-1/2" NPT
  • MAXIMUM SOLIDS HANDLING SIZE: 5/8"
  • IMPELLER TYPE: Engineered Thermoplastic, Enclosed Single-Vane
  • CORD LENGTH: 20'
  • CORD SIZE: 14/3; Type: SJOW, SJOW-A
  • BODY CONSTRUCTION: Cast Iron
  • MAXIMUM LIQUID TEMPERATURE: 140°F (60°C)

Myers P Series Cast Iron Effluent S.T.E.P. Pump Performance Data


WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.govWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

MYERS LIMITED WARRANTY

Myers® warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period shown below

ProductWarranty Period whichever occurs first:
Jet pumps, small centrifugal pumps, submersible pumps and related
accessories
12 months from date of original installation, or 18 months from date of manufacture
Fibrewound Tanks5 years from date of original installation
Fibrewound Tanks5 years from date of original installation
Sump/Sewage/Effluent Products12 months from date of original installation, or 36 months from date of manufacture
Battery Backup Units
MBSP-2, MBSP-2C
MBSP-3, MBSP-3C
12 months from date of original installation, or 18 months from date of manufacture
24 months from date of original installation, or 30 months from date of manufacture
Wastewater Solids Handling Pumps12 months from date of shipment from factory or 18 months from date of manufacture

Our warranty applies only where such products are used in compliance with the requirements of the applicable product catalog and/or manuals. For additional information, please refer to the applicable standard limited warranty featured in the product manual.

Our warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, improper installation, or improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase power through a phase converter will void the warranty. Note also that three phase motors must be protected by three-leg, ambient compensated, extra-quick trip overload relays of the recommended size or the warranty is void.

Your only remedy, and MYERS’s only duty, is that MYERS repair or replace defective products (at MYERS’s choice). You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered. No request for service will be accepted if received after the Warranty Period has expired. This warranty is not transferable.

MYERS SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.

THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN.

Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an implied warranty, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from state to state.

This Limited Warranty is effective April 1, 2014 and replaces all undated warranties and warranties dated before April 1, 2014.

We've been helping customers since 1953

Trust Guard Security Scanned