Orenco MF Liquid Level Switch Assembly Specifications
- Three (3) Model "P" Normally Open Signal-Rated Switch (contact is open when float switch is hanging)
- The Control Switch Turns on (closes) When the Float Tips Slightly Above Horizontal Signaling a High Level, and Turns Off (opens) When the Float Drops Slightly Below Horizontal.
- 2-inch (76-mm) Drawdown
- Super Vu-Tron® Cords: Flexible 2-Conductor (UL, CSA) SJOOW
- UL Listed for use in potable Water and Sewage.
- CSA Certified
- Approved for Intrinsically Safe Relays (very low amperage)
- One (1) Model "N" Normally Closed Signal-Rated Switch (contact is open when float switch is floating)
- The Control Switch Turns on (closes) When the Float Tips Slightly Below Horizontal Signaling a Low Level, and Turns Off (opens) When the Float Raises Slightly Above Horizontal.
- 2" (76-mm) Drawdown
- Super Vu-Tron® Cords: Flexible 2-Conductor (UL, CSA) SJOOW
- UL Listed for use in Potable Water and Sewage.
- CSA Certified
- Approved for Intrinsically Safe Relays (very low amperage)
- 45" Stem Length
- FS - Float Height not Established and Intended to be "Field Set" Per Project Requirements
- 10' Cord Lengths
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov