SJE-Rhombus Model 112 - Single Phase Simplex Motor Contactor Control Panel
This latest generation Model 112 control panel controls one 120, 208, or 240 VAC single phase pump in water and sewage installations. This panel includes a new innovative simplex controller for pump control and alarm; including float status LEDs, control/alarm power on/off switch with LED indicator, pump run LED, HOA switch, auxiliary contacts and more!
The Model 112 control panel features built in pump failure and float our of sequence detection. In addition, there are three user selectable field programmable options: alarm steady state or flashing: alarm auto reset or manual reset; and optional seal failure alarm beacon plus horn activation
Note: SJE Rhombus recommends separate pump and control/alarm power sources
SJE-Rhombus Model 112 - Single Phase Simplex Motor Contactor Control Panel Features
- Touch Safe Circuit Board Housing and Low Voltage 24 VDC Float Circuits
- Alarm (field programmable to flash)
- Alarm Automatic Reset (field programmable to manual alarm reset)
- Float Out-of-Sequence Detection
- Pump Contactor Failure Detection
- Controller Protected by Three Auto Resettable Fuses (control, alarm and pump 1)