Littelfuse LSRX-C Load Sensor Specifications
Input Characteristics
- Operating Current . . . . . . . . . . . . . . . . . . 5-200A Continuous
- Minimum Pull-in Current . . . . . . . . . . . . . 4.5A (typical), 7.0A (max)*
- Power . . . . . . . Induced from AC conductor
Relay Output Rating (SPST-Form A)
- Pilot Duty . . . . . . . . . . . . . . . . . . 480VA @ 240VAC, B300
- General Purpose. . . . . . . . . . . . . . . . . . . . . . . .5A @ 240VAC
Maximum Conductor Diameter . . . . . . . . . 0.7 in.
Output Terminals. . . . . . . . . . . . . . . . . . . depluggable screw terminals
Torque Rating . . . . . . . . . . . . . . . . . .3.0 in.-lbs.
Temperature Range
- Operating . . . . . . . . . . . . . . . . . . -20° to 70°C (-4° to 158°F)
- Storage . . . . . . . . . . . . . . . .-40° to 80°C (-40° to 176°F)
Hole Size . . . . . . . . . . . . . . .0.72” diameter
Wire Size . . . . . . . . . . . . . . .12-26 AWG
Output Relay Status Indicator . . . . . . . . . . . . . LED
Relative Humidity . . . . . . . . . . . . . 10-95%, non-condensing per IEC 68-2-3
Electrostatic Discharge (ESD) . . . . . . . . . IEC 61000-4-2, Level 2, 4kV contact, 4kV air
Fast Transient Burst . . . . . . . . . IEC 61000-4-4, Level 3, 2kV power, 1kV input/output
Surge
- IEC . . . . . . . . . . . . . . . . . . 61000-4-5, Level 3, 2kV line-to-line; 2kV line-to-ground
Safety Marks
- UL . . . . . . . . . . . . . . . . . . UL508 Recognized (File #E68520)
- CE . . . . . . . . . . . . . . . . IEC 60947
Weight . . . . . . . . . . . . . . .4.8oz
Mounting Method . . . . . . . . . . . . . . Surface Mount
*Conductors may be looped for smaller motor applications.
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov