Littelfuse 460-15-100-LLS Seal Leak Detector Specifications
Control Voltage . . . . . . . . . . . . 110 - 120 VAC nominal
Frequency
. . . . . . . . . . . . . . . . . . . . . 50 or 60 Hz (Note: 50Hz will increase all delay timers by 20%)
Sensitivity . . . . . . . . . . . . . . . . . . . . . 100kΩ
Functional Characteristics
- Probe Sense Voltage . . . . . . . . . . . . . . . . 5vdc pulsed
- Debounce Time Delay . . . . . . . . . . . . . . . . 2-60 seconds
Output Contact Rating
- (Two Form A-DPST) . . . . . . . . . . . . . . . . . .360VA @ 240VAC Pilot Duty
- . . . . . . . . . . . . . . . . . . . . . . . . . . . . or 8A @ 240VAC General Purpose
Temperature Range
- Operating . . . . . . . . . . . . . . . . . -40° to 70°C (-40° to 158°F)
- Storage . . . . . . . . . . . . . . . . . -40° to 80°C (-40° to 176°F)
Power Consumption
. . . . . . . . . . . . . 2 Watts (Max.)
Class of Protection . . . . . . . . . . . . . .IP20, NEMA 1 (finger safe)
Relative Humidity . . . . . . . . . . . . . .10-95%, non-condensing per IEC 68-2-3
Terminal Torque. . . . . . 4.5 in.-lbs
Wire . . . . . . . . . . . . . 12-20 AWG
Electricostatic Discharge (ESD). . . . IEC 61000-4-2, Level 3, 6kV contact, 8kV air
RFI, Radiated. . . . . . 150 MHz, 10V/m
Fast Transient Burst . . . . IEC 61000-4-4, Level 3, 3.5kV input power and controls
Surge
- IEC . . . . . . . . . . . . . . IEC 61000-4-5, Level 3, 4kV line-to-line; Level 4, 4kV line-to-ground
- ANSI/IEEE . . . . . . C62.41 Surge and Ring Wave Compliance to a level of 6kV line-to-line
- Hi-Potential Test . . . . . . . . . . . . . . Meets UL508 (2 x rated V +1000V for 1 minute)
Safety Marks
- UL . . . . . . . . . . . . . . . . . UL508 (File #E68520)
- CE . . . . . . . . . . . . . . . . . IEC 60947-6-2
Enclosure . . . . . . . . . . . . . . . . . . . . . Polycarbonate
Weight . . . . . . . . . . . . . . . . . . . . . . . . 16 oz.
Mounting Method
. . . . . . . . . . . 35 mm DIN rail or Surface Mount
(#6 or #8 screws)
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov