Littelfuse PC-102CICI-DL Dual Seal Leak Detector Product Specifications
Line Voltage . . . . . . . . . . . . 120 VAC Nominal
Frequency . . . . . . . . . . . . 50/60Hz
Probe Sense Voltage . . . . . . . . . 5vdc pulsed
Sensitivity . . . . . . . . . . . . . .4.7k-100kΩ
Sensitivity (for temp) . . . . . . . . . . . . Selectable 4kΩ with DIP switches
Input Logic . . . . . . . . . . . . . . . . . . . . . Direct or inverted<
Debounce Time Delay . . . . . . . . . . . . . . . . . . . . . 0.5 or 2 seconds
Relay Output Rating
- 2 Form C Isolated. . . . . . . . . . . . . . . . . . .180VA @ 120VAC, C150 Pilot Duty
- . . . . . . . . . . . . . . . . . . . . . 5A @ 240VAC General Purpose
Temperature Range . . . . . . . . . . . . . . . . . . . . . -20° to 55°C (-4° to 131°F)
Maximum Input Power . . . . . . . . . . . . . . . . . . . . . 2 W
Depluggable Connector . . . . . . . . . . . . . Phoenix Contact-Series MSTB plugs
Output Relay Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . LEDs
Terminal Torque . . . . . . . . . . . . . . . . . . . . . . . .4.5 in.-lbs
Wide Range . . . . . . . . . . . . . . . . . . . . . . . .12-20 AWG
Electrostatic Discharge (ESD) . . . . . . . . . IEC 61000-4-2, Level 3, 6kV contact, 8kV air
Radio Frequency Immunity (RFI) . . . . . . . . . IEC 61000-4-3, Level 3, 10V/m
Fast Transients . . . . . . . . . IEC 61000-4-4, Level 3, 4kV input power 2kV inputs/outputs
Safety Mark
- UL . . . . . . . . . . . . . . . . . . . . . . . UL508 (File #E68520)
Weight . . . . . . . . . . . . . . . . . . . . . . . . 14.4 oz.
Mounting Method
. . . . . . . . . . . 35mm DIN rail or Surface Mount (#6 or #8 screws)
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov