Prev Next

Myers WG20-03 Submersible Grinder Pump 2.0 HP 200V 3PH

Price: $3,984.00
Quantity:
+ -
Usually ships within 5 weeks
SKU: MYR21575D001


Shipping Weight:
80.0 LBS
Shipping Dimensions
Length: 10 In
Width: 12 In
Height: 19 In
WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.gov

myerslogopumps1.png

Myers Model WG20/WGX20 Submersible Grinder Pump Description

The Myers WG20/WGX20 are rugged 2 horsepower submersible centrifugal grinder pumps designed for residential, light commercial, industrial or municipal applications. They are especially designed for grinder pump applications requiring high flows at low to moderate heads. The WG20/WGX20 features a recessed impeller design to efficiently grind typical domestic sewage solids into a fine slurry. These pumps are available in standard construction and construction for use in Class 1, Group D hazardous locations.

Myers Model WG20/WGX20 Submersible Grinder Pump Typical Application

  • Residential
  • Light Commercial
  • Industrial and Municipal Applications

Myers Model WG20/WGX20 Submersible Grinder Pump Superior Features

  • Stator-2 HP, 3450 RPM, 1 and 3 Phase. Press Fit for Perfect Alignment and Best Heat Transfer. Oil-Filled Motor Conducts Heat and Lubricate Bearings.
  • Cable Entry System Provides Double Seal Protection. Cable Jacket Sealed by Compression Fitting. Individual Wires Sealed by Epoxy Potting.
  • Heat Sensor Protects Motor from Burnout Due to Excessive Heat from Any Overload Condition. Automatically Resets when Motor has Cooled.
  • Ball Bearings Upper and Lower Ball Bearings Support Shaft and Rotor and Take Axial and Radial Loads.
  • Heavy 416 SST Shaft Corrosion Resistant. Reduces Shaft Deflection Due to Grinding Loads.
  • Shaft Seals Double Tandem Mechanical Shaft Seals Protect Motor. Oil-Filled Seal Chamber Provides Continuous Lubrication.
  • Seal Leak Probe Detects Water in Seal Housing; Activates Warning Light in Control Panel.
  • Volute Case Cast Iron, 1¼" NPT Vertical Discharge.
  • Impeller SST Recessed Impeller Handles Ground Slurry Without Clogging or Binding. Provides Unobstructed Flow Passage. Reduces Radial Loads. Pump-Out Vanes Help Keep Trash from Seal, Reduces Pressure at Seal Faces.
  • Sleeve Bearing Takes Radial Load; Provides Flame Path.
  • Grinder Assembly Grinder Impeller and Shredding Ring are Replaceable without Dismantling Pump. Constructed of 440 SST Hardened to 56-60 Rockwell.

Myers WG20-03 Submersible Grinder Pump Specifications

  • VOLTAGE: 3ø, 200V, 60Hz
  • HORSEPOWER: 2.0 HP
  • AMP DRAW (full load): 9.7
  • MOTOR TYPE: Oil-Filled for Maximum Heat Dissipation and Constant Bearing Lubrication
  • RPM: 3450
  • MAXIMUM HEAD: up to 105'
  • MAXIMUM CAPACITY: up to 45 GPM
  • SWITCH TYPE: Manual
  • MINIMUM SUMP DIAMETER: Simplex; 24" Duplex; 36"
  • DISCHARGE PIPE SIZE: 1-1/4" NPT Vertical
  • IMPELLER TYPE: SST, Recessed
  • CORD SIZE: 14-4
  • BODY CONSTRUCTION: Cast Iron
  • MAXIMUM LIQUID TEMPERATURE: 140°F (60°C)
  • CONTROL BOX REQUIRED

Myers Model WG20/WGX20 Submersible Grinder Pump Curve


WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.govWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

STANDARD LIMITED WARRANTY Pentair Myers® warrants its products against defects in material and workmanship for a period of 12 months from the date of shipment from Pentair Myers or 18 months from the manufacturing date, whichever occurs first – provided that such products are used in compliance with the requirements of the Pentair Myers catalog and technical manuals for use in pumping raw sewage, municipal wastewater or similar, abrasive-free, noncorrosive liquids.

During the warranty period and subject to the conditions set forth, Pentair Myers, at its discretion, will repair or replace to the original user, the parts that prove defective in materials and workmanship. Pentair Myers reserves the right to change or improve its products or any portions thereof without being obligated to provide such a change or improvement for prior sold and/or shipped units.

Start-up reports and electrical schematics may be required to support warranty claims. Submit at the time of startup through the Pentair Myers website: http://forms.pentairliterature.com/startupform/startupform.asp?type=m. Warranty is effective only if Pentair Myers authorized control panels are used. All seal fail and heat sensing devices must be hooked up, functional and monitored or this warranty will be void. Pentair Myers will cover only the lower seal and labor thereof for all dual seal pumps. Under no circumstance will Pentair Myers be responsible for the cost of field labor, travel expenses, rented equipment, removal/reinstallation costs or freight expenses to and from the factory or an authorized Pentair Myers service facility.

This limited warranty will not apply: (a) to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with the printed instructions provided; (b) to failures resulting from abuse, accident or negligence; (c) to normal maintenance services and parts used in connection with such service; (d) to units that are not installed in accordance with applicable local codes, ordinances and good trade practices; (e) if the unit is moved from its original installation location; (f) if unit is used for purposes other than for what it is designed and manufactured; (g) to any unit that has been repaired or altered by anyone other than Pentair Myers or an authorized Pentair Myers service provider; (h) to any unit that has been repaired using non factory specified/OEM parts.

Warranty Exclusions: PENTAIR MYERS MAKES NO EXPRESS OR IMPLIED WARRANTIES THAT EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. PENTAIR MYERS SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR PURPOSE.

Liability Limitation: IN NO EVENT SHALL PENTAIR MYERS BE LIABLE OR RESPONSIBLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES RESULTING FROM OR RELATED IN ANY MANNER TO ANY PENTAIR MYERS PRODUCT OR PARTS THEREOF. PERSONAL INJURY AND/OR PROPERTY DAMAGE MAY RESULT FROM IMPROPER INSTALLATION. PENTAIR MYERS DISCLAIMS ALL LIABILITY, INCLUDING LIABILITY UNDER THIS WARRANTY, FOR IMPROPER INSTALLATION. PENTAIR MYERS RECOMMENDS INSTALLATION BY PROFESSIONALS.

Some states do not permit some or all of the above warranty limitations or the exclusion or limitation of incidental or consequential damages and therefore such limitations may not apply to you. No warranties or representations at any time made by any representatives of Pentair Myers shall vary or expand the provision hereof.

We've been helping customers since 1953

Trust Guard Security Scanned