Prev Next

SJE-Rhombus Model 32XR Three Phase Duplex Alternating Pump Control Panel w/Override

Price: $5,003.50
Quantity:
+ -
Usually ships within 4 days
SKU: CP-SJE32XR806X
Voltage, Pump Amperage, Number of Floats, Special Instructions *
Max: 250 character(s)
Pump Full Load Amps:

Tool Tip: Horsepower to Amperage

Float Switch Application:

Panel Options, Select all that are standard and that apply:

Update price


Shipping Weight:
30.0 LBS
Shipping Dimensions
Length: 18 In
Width: 10 In
Height: 16 In
WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.gov

sjerhombuslogo6002018.jpg

SJE-Rhombus Model 32XR - Three Phase Duplex Alternating Pump Control Panel

The Model 32XR Control Panel is designed to alternately control two three phase pumps in industrial and commercial water and sewage systems using a 4-20 mA level transmitter. In addition to transmitter control, this system will accept a high water float to activate the alarm and run both pumps. This panel also provides a redundant low level cutout, seal fail and thermal cutout for both pumps. Common applications include lift stations, pump chambers and irrigation systems.

The 32XR Three Phase Duplex Control Panel is designed to be rugged, simple and versatile. One panel handles three voltages and a wide range variety of pump motor amperage requirements by simply field installing overload modules - up to 32 amps each. The 32XR operates with a 4-20mA level transducer which can be configured for either 1 or 2 backup float switches. The 32XR features the simple to operate LCX3 controller with an intuitive menu and graphic display.

SJE-Rhombus Model 32XR - Three Phase Duplex Alternating Pump Control Panel Features

    Panel Features:
  • TYPE 4X fiberglass with mounting feet (for indoor or outdoor use)
  • Padlockable Latch Provides added Safety
  • IEC HP Rated Motor Starters Perform Contactor/Circuit Breaker Function, up to 32 FLA (requires separate overload modules). Provides Location for Field Wiring of Incoming Power and Pumps
  • Multi-Tap Transformer (208/230/460 VAC primary) Provides 120 VAC Control/Alarm Voltage
  • Class 10 Ambient Overload Modules (purchased separately) Provide Overload-Short Circuit, Phase Failure-Phase Imbalance and Ground Fault Protection (equipment protection only); Accessible Through Inner Door (two overload-short circuit, field installation required)
  • Terminal Block Provides Connections for Field Wiring Ground Wires for Incoming Power and Pumps
  • Ground Lugs Provide Location for Field Wiring Ground Wires for Incoming Power and Pumps
  • Lightning Arrestor Provides Surge Suppression with Immediate Indication if Replacement is Required
  • Power Supply Provides 24 VDC to LCX3 Controller and Backup Float(s)
  • LCX3 Controller Sequences Pumps On and Off in Response to a Change in Level Input Provided by a 4-20 mA Sensor and also Provides Pump Over Temp, Seal Fail, Pump Run, Pump Fail, High Level and Low Level Monitoring Indications
  • Hand/Off/Auto Switches for Manual Pump Control
  • Green Pump Run Indicator Lights Identify Pump Called to Run Condition
  • Inner Door Provides Added Safety for Panel Operation
  • Red Alarm Beacon Provides 360°Visual Check of Alarm Condition
  • Alarm Horn Provides Audible Warning of Alarm Condition
  • Test/Normal/Silence Switch Allows Horn and Light to be Tested and Horn to be Silenced in an Alarm Condition. Alarm Automatically Resets Once Alarm Condition is Cleared
  • Overload Modules(sold separately, each panel requires two modules):
    • Overload Module, 3.0-12.0 FLA
    • Overload Module, 8.0-32.0 FLA
  • UL/cUL Listed
  • Dual Safety Certification for United States and Canada
  • Five-Year Limited Warranty

SJE-Rhombus Model 32XR - Three Phase Duplex Alternating Pump Control Panel Specifications

    INNER DOOR FEATURES

    Inner Door Provides a Degree of Safety for Panel Operation

  1. TPC-X Controller Sequences Pumps On or Off in Response to a Change in Level Input Provided by a 4-20 mA Sensor and Also Provides Pump Over Temp, Seal Fail, Pump Run, Pump Fail, High Level and Low Level Monitoring Indications.
  2. Hand/Off/Auto Switches for Manual Pump Control
  3. Green Pump Run Indicator Lights Identify Pump Called to Run Condition
  4. Inner Door Provides Added Safety for Panel Operation
    PANEL COMPONENTS:
  1. Enclosure Measures 18" x 16" x 10" Type 4X Fiberglass with Mounting Feet (for indoor or outdoor use)
  2. Padlockable Latch Provides Added Safety. (Not Shown)
  3. IEC HP Rated Motor Starters Perform Contactor/Circuit Breaker Function, Up to 32 FLA (requires separate overload modules). Provides Location for Field Wiring of Incoming Power and Pumps.
  4. Multi-Tap Transformer (208/230/460 VAC primary) Provides 120VAC Control/ Alarm Voltage Along with Primary and Secondary Fusing.
  5. Class 10 Ambient Overload Modules (purchased separately) Provide Overload Short Circuit, Phase Failure-Phase Imbalance and Ground Fault Protection (equipment protection only); Accessible Through Inner Door (two overload modules required, field installation required).
  6. Terminal Blocks Provides Connections for Field wiring of Transmitter, Floats, Auxiliary Alarm Contact, Seal Fail and Thermal Cutout for Each Pump.
  7. Ground Lugs Provide Location for Field Wiring Ground Wires Incoming Power and Pumps.
  8. Lightning Arrestor Provides Surge Suppression with Immediate Indication if Replacement is Required.
  9. Power Supply Provides 24 VDC to LCX3 Controller and Backup Float(s).
  10. Red LED Beacon Provides 360 Degree Visual Check of Alarm Condition.
  11. Alarm Horn Provides Audible Warning of Alarm Condition (95 decibel rating). (Not Shown)
  12. Test/Normal/Silence Switch Allows Horn and Light to be Tested and Horn to be Silenced in an Alarm Condition. Alarm Automatically Resets Once Alarm Condition is Cleared. (Not Shown)

WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.govWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

SJE Rhombus Limited Warranty Policy

Five-Year Limited Warranty Policy We Stand Behind Our Products!

Effective for products manufactured after January 1, 2014

SJE-Rhombus warrants to the original consumer that this product shall be free of manufacturing defects for five years* after the date of consumer purchase. During that time period and subject to the conditions set forth below, SJE-Rhombus will repair or replace, for the original consumer, any component which proves to be defective due to defective materials or workmanship of SJE-Rhombus.

THE FIVE-YEAR LIMITED WARRANTY DOES NOT APPLY TO THE MOTOR START KIT COMPONENTS. SJE-RHOMBUS WILL WARRANTY MOTOR START KIT COMPONENTS, SUPPLIED BY SJE-RHOMBUS FOR ONE YEAR. SJE-RHOMBUS MAKES NO WARRANTIES OF ANY TYPE WITH RESPECT TO MOTOR START KITS SUPPLIED BY A CUSTOMER.

SJE-Rhombus warrants to the original consumer that this product shall be free of manufacturing defects for five years* after the date of consumer purchase. During that time period and subject to the conditions set forth below, SJE-Rhombus will repair or replace, for the original consumer, any component which proves to be defective due to defective materials or workmanship of SJE-Rhombus.

THE FIVE-YEAR LIMITED WARRANTY DOES NOT APPLY TO THE MOTOR START KIT COMPONENTS. SJE-RHOMBUS WILL WARRANTY MOTOR START KIT COMPONENTS, SUPPLIED BY SJE-RHOMBUS FOR ONE YEAR. SJE-RHOMBUS MAKES NO WARRANTIES OF ANY TYPE WITH RESPECT TO MOTOR START KITS SUPPLIED BY A CUSTOMER.

ELECTRICAL WIRING AND SERVICING OF THIS PRODUCT MUST BE PERFORMED BY A LICENSED ELECTRICIAN.

This warranty does not apply to: (a) damage due to lightning or conditions beyond the control of SJE-Rhombus; (b) defects or malfunctions resulting from units not installed, operated, or maintained in accordance with instructions provided, applicable local codes, ordinances, or accepted trade practices; (c) failures resulting from abuse, misuse, accident, or negligence; or (d) units repaired and/or modified without prior authorization from SJE-Rhombus.

Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

TO OBTAIN WARRANTY SERVICE: The consumer shall assume all responsibility and expense for removal, reinstallation, and freight. Any item to be repaired or replaced under this warranty must be returned to SJE-Rhombus, or such place as designated by SJE-Rhombus. Contact customer service at 1-888-DIAL-SJE (1-888-342-5753) for a Return Materials Authorization number (RMA) on any product being returned for a warranty claim.

ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY. SJE-RHOMBUS SHALL NOT, IN ANY MATTER, BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES AS A RESULT OF A BREACH OF THIS WRITTEN WARRANTY OR ANY IMPLIED WARRANTY.

*Build-A-Panel™ Plus Control Panels and Engineered Custom panels carry a two-year limited warranty (or as quoted). The pressure transducer included with VARIOspeed® products carries a one-year limited warranty.

We've been helping customers since 1953

Trust Guard Security Scanned