Prev Next

SJE-Rhombus Model IFS In-Site Single Phase 120/208/240V Simplex Control Panel

Price: $2,873.80
Quantity:
+ -
Usually ships within 4 days
SKU: CP-SJEIFIS11W100H4A8AC17J24E
Voltage, Pump Amperage, Number of Floats, Special Instructions *
Max: 250 character(s)
Model Type:

Alarm Package:

Enclosure Rating:

Starting Device:

Pump Full Load Amps:

Tool Tip: Horsepower to Amperage

Pump Disconnects:

Float Switch Application:

Redundant Off:

Option 24 & 29 C-Level Sensor Options:

Float Switch Selection (Option 17) ($ per float):

Cord Length:

Panel Options, Select all that are standard and that apply:

Update price


Shipping Weight:
20.0 LBS
Shipping Dimensions
Length: 18 In
Width: 16 In
Height: 10 In
WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.gov

sjerhombuslogo6002018.jpg

IFS In-Site Single Phase Simplex Control Panel

Get In-Site to Your On-Site™ with IFS In-Site® Event Monitoring Control Panels!

The IFS In-Site® Simplex control panel is designed to control one 120/208/240V single phase pump in water and sewage installations. The IFS panel features a simple, easy-to-use touch pad on the inner door for programming and system monitoring. The panel configuration can be easily converted to demand dose or timed dose in the field.

The IFS In-Site® panel monitors and records system events including pump run times, pump cycles, alarm conditions, power outages, service calls and more. Plug the flash drive (included) into the USB port located on the inner door of the IFS In-Site® control panel to download system events. The pre-loaded software on the flash drive formulates system data for you, creating reports quickly in an easy-to-read format so system conditions can be easily identified and corrected. In addition, the IFS In-Site® panel logs any changes made to the system settings which helps protect service providers, and tracks service calls made to the panel.

The optional C-Level™ sensor is a pressure transducer that senses the liquid level in the tank and sends a signal to the IFS panel. Pump activation levels can be adjusted by using the panel touch pad. C-Level™ CL40 sensor operating range is 3-39.9 inches (7.6-101.3 cm). C-Level™ CL100 sensor operating range is 3-99.5 inches (7.6-252.7 cm).

SJE-Rhombus Model IFS Single Phase Simplex Panel Features

    Touch Pad Features:
  • Level Status Indicators
  • Hand/Off/Automatic (HOA) Buttons
  • Pump Run Indicators
  • LED Display Shows System Information (see below)
  • Next Push Button
  • Up and Set Push Buttons
  • LED Display Features:
  • Mode
  • Pump Elapsed Time (hh:mm)
  • Events (cycles)
  • Alarm Counter
  • Float Error Counter
  • Timed Dose Override Counter (TD only)
  • On/Off Times (TD only)
  • Sequence On/Off Times (TD only)
  • Level in Inches or Centimeters (C-Level™ sensor only)
  • Panel Features:
  • NEMA 4X Enclosure
  • Red Alarm Beacon Provides 360° Visual Check of Alarm Condition
  • Exterior Alarm Test/Normal/Silence Switch Allows Horn and Light to be Tested and Horn to be Silenced in an Alarm Condition; Alarm Automatically Resets Once Alarm Condition is Cleared
  • Alarm Horn Provide Audio Warning of Alarm Condition
  • Circuit Breaker (optional) Provides Pump Disconnect and Branch Circuit Protection
  • Power Relay Controls Pump by Switching Electrical Lines; Definite Purpose Contactor Used when Pump FLA is Above 15
  • Float Connection Terminal Block
  • Incoming Control/Alarm Terminal Block
  • Control Power Indicator/Fuse
  • Alarm Power Indicator/Fuse
  • Ground Lug
  • Incoming Pump Power Connections
  • RF Filter
  • Power Supply
  • USB Port
  • Manuals Report Switch
  • Five-Year Limited Warranty on Panel
  • One-Year Limited Warranty on C-Level™ Sensor
  • UL/cUL Listed

SJE-Rhombus Model IFS Single Phase Simplex Panel Components

    TOUCH PAD FEATURES:
  1. Level Status Indicators Illuminate when Floats or Set Points are Activated. Alarm will Activate if a Float Operates out of Sequence.
  2. HOA (Hand-Off-Automatic) Buttons with Indication Control Pump Mode. Hand Mode Defaults to Automatic when Stop Level or Redundant Off Level is Reached.
  3. Pump Run Indicator Illuminates when Pump is called to Run.
  4. LED Display Shows System Information Including: Level in Inches or Centimeters (C-Level™ sensor only), Mode, Pump Elapsed Time (hh:mm), Events (cycles), Alarm Counter, Float Error Count, Timed Dose Override Counter (timed dose only), Pump ON/OFF Times (timed dose only), and Sequence ON/OFF Times (timed dose only).
  5. NEXT Push Button Toggles Display.
  6. UP and SET Push Buttons used to Set Pump ON/OFF Times (timed dose only), date and hour, activation levels (C-Level™ only).
  7. Control Fuse
  8. Alarm Fuse
  9. USB Port for Flash Drive to Download Time-Stamped System Events.
  10. Manual Report Switch Date and Time Stamps Service Calls.
    PANEL COMPONENTS:
  1. Enclosure Base Measures 14 X 12 X 6 inches (35.56 X 30.48 X 15.24 cm). NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use). Note: Options, Voltage, and Amp Range Selected May Change Enclosure Size and Component Layout.
  2. Red Alarm Beacon Provides 360° Visual Check of Alarm Condition.
  3. Exterior Alarm Test/Normal/Silence Switch Allows Horn and Light to be Tested and Horn to be Silenced in an Alarm Condition. Alarm Automatically Resets Once Alarm Condition is Cleared.
  4. Alarm Horn Provides Audio Warning of Alarm Condition (83 to 85 decibel rating).
  5. Circuit Breaker (optional) Provides Pump Disconnect and Branch Circuit Protection.
  6. Power Relay Controls Pump by Switching Electrical Lines. Definite Purpose Contactor Used when Pump Full Load Amps are Above 15.
  7. Float Connection Terminal Block
  8. Incoming Control/Alarm Power & Pump Terminal Block
  9. Control Power Indicator/Fuse Indicator Light Illuminates if Control Power is Present in Panel. Alarm will Activate if Control Fuse is Blown.
  10. Alarm Power Indicator/Fuse Indicator Light Illuminates if Alarm Power is Present in Panel.
  11. Ground Lug
  12. Incoming Pump Power Connections
  13. RF Filter
  14. Power Supply
  15. Five-Year Limited Warranty
  16. UL/cUL Listed
  17. NOTE: Schematic/Wiring Diagram and Pump Specification Label are Located Inside the Panel on Enclosure Cover.


WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.govWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

SJE Rhombus Limited Warranty Policy

Five-Year Limited Warranty Policy We Stand Behind Our Products!

Effective for products manufactured after January 1, 2014

SJE-Rhombus warrants to the original consumer that this product shall be free of manufacturing defects for five years* after the date of consumer purchase. During that time period and subject to the conditions set forth below, SJE-Rhombus will repair or replace, for the original consumer, any component which proves to be defective due to defective materials or workmanship of SJE-Rhombus.

THE FIVE-YEAR LIMITED WARRANTY DOES NOT APPLY TO THE MOTOR START KIT COMPONENTS. SJE-RHOMBUS WILL WARRANTY MOTOR START KIT COMPONENTS, SUPPLIED BY SJE-RHOMBUS FOR ONE YEAR. SJE-RHOMBUS MAKES NO WARRANTIES OF ANY TYPE WITH RESPECT TO MOTOR START KITS SUPPLIED BY A CUSTOMER.

SJE-Rhombus warrants to the original consumer that this product shall be free of manufacturing defects for five years* after the date of consumer purchase. During that time period and subject to the conditions set forth below, SJE-Rhombus will repair or replace, for the original consumer, any component which proves to be defective due to defective materials or workmanship of SJE-Rhombus.

THE FIVE-YEAR LIMITED WARRANTY DOES NOT APPLY TO THE MOTOR START KIT COMPONENTS. SJE-RHOMBUS WILL WARRANTY MOTOR START KIT COMPONENTS, SUPPLIED BY SJE-RHOMBUS FOR ONE YEAR. SJE-RHOMBUS MAKES NO WARRANTIES OF ANY TYPE WITH RESPECT TO MOTOR START KITS SUPPLIED BY A CUSTOMER.

ELECTRICAL WIRING AND SERVICING OF THIS PRODUCT MUST BE PERFORMED BY A LICENSED ELECTRICIAN.

This warranty does not apply to: (a) damage due to lightning or conditions beyond the control of SJE-Rhombus; (b) defects or malfunctions resulting from units not installed, operated, or maintained in accordance with instructions provided, applicable local codes, ordinances, or accepted trade practices; (c) failures resulting from abuse, misuse, accident, or negligence; or (d) units repaired and/or modified without prior authorization from SJE-Rhombus.

Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

TO OBTAIN WARRANTY SERVICE: The consumer shall assume all responsibility and expense for removal, reinstallation, and freight. Any item to be repaired or replaced under this warranty must be returned to SJE-Rhombus, or such place as designated by SJE-Rhombus. Contact customer service at 1-888-DIAL-SJE (1-888-342-5753) for a Return Materials Authorization number (RMA) on any product being returned for a warranty claim.

ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY. SJE-RHOMBUS SHALL NOT, IN ANY MATTER, BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES AS A RESULT OF A BREACH OF THIS WRITTEN WARRANTY OR ANY IMPLIED WARRANTY.

*Build-A-Panel™ Plus Control Panels and Engineered Custom panels carry a two-year limited warranty (or as quoted). The pressure transducer included with VARIOspeed® products carries a one-year limited warranty.

We've been helping customers since 1953

Trust Guard Security Scanned