Prev Next

Myers WHR5-03 Sewage Pump 0.5 HP 200V 3 PH Manual 20' Cord

Price: $1,575.00
Quantity:
+ -
Usually ships within 2 weeks
SKU: MYRWHR503


Shipping Weight:
77.0 LBS
Shipping Dimensions
Length: 24 In
Width: 16 In
Height: 16 In
WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.gov

myerslogopumps1.png

Myers WHR Series Sewage Pump Description

The Myers® WHR series sewage pumps feature all cast iron construction to withstand the most extreme conditions. Available in single seal, and double seal models for additional protection against water leakage. The enclosed two-vane impeller provides high-efficiency pumping and will handle stringy, trashy 2" solids without clogging. Designed for sewage and effluent and can be used for applications requiring high heads.

Myers WHR Series Sewage Pump Typical Applications

Residential and Commercial Sewage, Domestic Wastewater and Septic Systems

Myers WHR Series Sewage Pump Features

  • Non-Clog Design: Recessed Impeller Provides Maximum Efficiency and Eliminates Jamming Between Volute Case - Cast Iron Construction.
  • Leak Detection: Leak Probe Senses Water Leakage Past Seal (Dual Seal Motors Only).
  • Cool Running: Durable, Oil-Filled Motor for Continuous Bearing Lubrication and Maximum Heat Dissipation.
  • Powerful Starts: High-Torque, Permanent Split Capacitor (PSC) Motor; No Starting Switches or Relays to Wear Out.
  • Thermal Protection: Heat Sensor Overload Protection with Automatic Reset when Motor Cools to a Safe Operating Temperature.
  • High-Capacity Handling: Passes Full 2" Solids.

Myers WHR5-03 Series Sewage Pump Specifications

  • VOLTAGE: 3ø, 200V, 60Hz
  • HORSEPOWER: 0.5 HP
  • AMP DRAW (full load): 3.6
  • MOTOR TYPE: Permanent Split Capacitor (PSC)
  • MAXIMUM HEAD: up to 24'
  • MAXIMUM CAPACITY: up to 130 GPM
  • SWITCH TYPE: Manual
  • MINIMUM SUMP DIAMETER: Simplex: 24” Duplex: 30”
  • DISCHARGE PIPE SIZE: 2.0" NPT (3.0" optional)
  • MAXIMUM SOLIDS HANDLING SIZE: 2.0"
  • IMPELLER TYPE: Cast Iron, Vortex
  • CORD LENGTH: 20'
  • CORD SIZE: 16/4; Type: SJOW/SJOW-A
  • BODY CONSTRUCTION: Cast Iron
  • MAXIMUM LIQUID TEMPERATURE: 140°F (60°C)

Myers WHR Series Sewage Pump Performance Data

whrcurve.jpg


WARNING Cancer and Reproductive Harm - www.P65Warnings.ca.govWARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

MYERS LIMITED WARRANTY

Myers® warrants to the original consumer purchaser (“Purchaser” or “You”) of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period shown below

ProductWarranty Period whichever occurs first:
Jet pumps, small centrifugal pumps, submersible pumps and related
accessories
12 months from date of original installation, or 18 months from date of manufacture
Fibrewound Tanks5 years from date of original installation
Fibrewound Tanks5 years from date of original installation
Sump/Sewage/Effluent Products12 months from date of original installation, or 36 months from date of manufacture
Battery Backup Units
MBSP-2, MBSP-2C
MBSP-3, MBSP-3C
12 months from date of original installation, or 18 months from date of manufacture
24 months from date of original installation, or 30 months from date of manufacture
Wastewater Solids Handling Pumps12 months from date of shipment from factory or 18 months from date of manufacture

Our warranty applies only where such products are used in compliance with the requirements of the applicable product catalog and/or manuals. For additional information, please refer to the applicable standard limited warranty featured in the product manual.

Our warranty will not apply to any product that, in our sole judgement, has been subject to negligence, misapplication, improper installation, or improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase power through a phase converter will void the warranty. Note also that three phase motors must be protected by three-leg, ambient compensated, extra-quick trip overload relays of the recommended size or the warranty is void.

Your only remedy, and MYERS’s only duty, is that MYERS repair or replace defective products (at MYERS’s choice). You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered. No request for service will be accepted if received after the Warranty Period has expired. This warranty is not transferable.

MYERS SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.

THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN.

Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on the duration of an implied warranty, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from state to state.

This Limited Warranty is effective April 1, 2014 and replaces all undated warranties and warranties dated before April 1, 2014.

We've been helping customers since 1953

Trust Guard Security Scanned